By using our website, you agree to the use of our cookies.
By using our website, you agree to the use of our cookies.
+44 (0) 1590 641223 sales@r-p-r.co.uk Unit 1 | Barnes ln | Milford on Sea | SO41 0AP MON-FRI 9-5

WS-15A Wind & Weather Display

£513.18 exVAT

£615.82 incVAT

The WS-15A is a cost effective, compact and easy to read 40 character weather display delivering meteorological data including wind speed in a choice of measurement units and wind direction in degrees. A volt free relay (control) output or, a rated +VDC (supply) switched output is controlled by a user defined wind speed threshold alarm, that can be set either as a high or low alarm activating for example an audible alarm unit or a door control switch.

Product Description

WS-15A Weather Display Description

The WS-15A wind and weather display is compatible with a wide range of meteorological sensors including Gill’s WindSonic, MetPak, WindObserver and WindMaster sensors plus LCJ Capteurs CV7 and the Calypso ultrasonic anemometers range and other sensors outputting NMEA wind data.

Data can be viewed on the 40 character display, showing wind speed in a choice of measurement units and wind direction in degrees, as a wind arrow and as cardinal points. Additional weather parameters including temperature, pressure, relative humidity and dew point are displayed when connected to a Gill MetPak sensor and sonic temperature and speed of sound are available with the Gill WindObserver sensor.

The unit is operated using five tactile buttons with displayed prompts making configuration a simple process. Adjustable settings include; sensor alignment, wind speed alarm, wind speed units, pressure calibration, sensor input, display contrast and backlight. The display has an adjustment lock to avoid inadvertent alteration of the wind speed alarm and sensor settings.

An RS232 output is provided for connecting for example:
• WeatherFile Communication Unit (WCU); allowing data to be transferred to our cloud solution WeatherFile.com.
• SpaceLogger.W10 wind & weather data logger; for local standalone data logging.
• Computer or radio modem.

A volt free relay (control) output, or, a rated +VDC (supply) switched output is controlled by the WS-15A alarm settings allowing the user to configure a wind speed alarm that can be set as either a high or a low alarm with adjustable hold-off and hold-on times to avoid false alarm events. The output can activate a local audible, visual or dual (audible & visual) alarm or for example a door control switch.

When using the RS422/RS485 input, the display can often eliminate the need for a separate RS422/RS485 to RS232 converter. There is also an optically isolated input for when extra isolation of the sensor is required.

Several WS-15A display units can be connected to one sensor or daisy chained using the RS232 output.

WS-15A display is compatible with:

• Gill WindSonic sensors
• Gill WindObserver sensors
• Gill GMX sensors
• Gill MetPak & MetPak Pro Weather Stations
• LCJ Capteurs CV7-V (T) ultrasonic sensor
• Calypso Wired ultrasonic sensors
• NMEA sensors

Typical Applications

• Meteorological data collection
• Wind farm surveying and operations
• Construction industry including crane operations
• Education and research projects
• Aviation operations
• Data buoys
• Health and safety
• Sports and outdoor activities
• Agriculture & Horticulture
• HVAC
• Transport – roads, bridges & tunnels
• Marine & offshore
• Turbulence
• Waste & recycling

Features

• Digital display of wind speed and direction
• Wind speed in m/s, knots, mph, km/h, or ft/min
• Wind direction arrow with selectable cardinal points
• High or low wind speed alarm with, hold-on and hold-off period to inhibit false alarms
• Volt free relay alarm output
• Easy to operate display with user prompts
• Clear alpha-numeric display, backlight with contrast control
• Simple to install with screwless terminals
• Rugged construction, IP65
• Will display wind direction and wind speed from a wide range of sensors
• Gill WindSonic
• Gill MetPak
• Gill MaxiMet (GMX)
• NMEA 0183 sensors that output the MWV sentence
• Data inputs: RS232, RS422/RS485 or NMEA (optically isolated)
• Will display additional functions from MetPak and WindObserver sensors
• Two RS232 data outputs for connection to datalogger and/or additional WS-15A displays
• Sensor/system status code display for diagnostics

Physical Dimensions Width: 140mm (including mounting feet)
Depth: 100mm (including cable glands)
Height: 65mm (including mounting feet)
Panel Dimensions 120mm x 80mm
Weight 0.35 kg
Mounting Surface mounted
Material Light Grey ABS Polycarbonate Blend
Cable access 4 waterproof glands
Power Power requirements 9 to 30 Vdc
Current at 12 Vdc 20mA  to 35mA (backlight on)
Supply Input protection Polarity reversal protected. Internal fuse 500mA slo-blo (Littelfuse 0454500 or equivalent)
Connection Internal lever action terminals for AWG 28 to 22 conductors (0.32 to 0.65mm diameter)
Environmental Temperature Operating range: -10°C to +70°C
Sealing IP65
EMC EN61326:1977, EN60945:2002 (emissions)
EN61326:1997 (immunity)
Display Operation Display Two line 20 character dot matrix super-twist LCD with backlight
Operation 5 keys on front of unit for menu navigation, data entry and control functions
Functions Wind speed
Wind direction
Wind speed high/low alarm with hold on and hold off period
Pressure (when using MetPak II weather station)
Relative Humidity (when using MetPak II weather station)
Air Temperature (when using MetPak II weather station)
Dew point (when using MetPak II weather station)
Sensor supply voltage (when using MetPak II weather station)
Sensor alignment adjustment
Wind speed measurement units selection
Contrast
Backlight
Sensor selection
Radio signal strength
Pressure calibration setting (when using MetPak II weather station)
Speed of Sound (when using WindObserver II sensor)
Sonic temperature (when using WindObserver II sensor)
Data output configuration
Wind direction display Digital 3 digits with wind arrow and cardinal points
Wind speed display Digital display with units selection from kts, mph, km/h, fpm, m/s
Sensor status Error code displayed for sensor/communications diagnostics
Connectivity Wind sensor WindSonic sensor outputting RS232 or RS422/485 at 9600 baud in factory default format
MetPak II weather station outputting RS232 or RS422/485 at 9600 baud in factory default format
WindObserver II outputting RS422/485 at 9600 baud in factory default format
Sensors outputting NMEA 0183 MWV sentence at 4800 baud
Gill MaxiMet GMX200, GMX240, GMX500, GMX501, GMX541, GMX550, GMX551, GMX600 The sensors should be set their default output with wind direction and wind speed as the first two fields after the sensor identifier (Q). If RS485 is used the baud rate should be set to 9600.
Alarm output Volt free relay output. Max 24Vdc at switching current of 0.5 amperes. Contact resistance 0.150 ohm maximum
Data output RS232 for connection to a WindLogger or other data logger, computer, communications equipment or additional WS-15A display units
Radio Modem Digi Xstream-PKG radio modem as supplied by RPR Ltd

The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change

Data Sheets
Download PDF WS-15A Ultrasonic Wind System – Data Sheet
User Manual
Download PDF WS-15A Display Unit User Handbook – Issue 15
has been added to the cart. View Cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Price
  • Additional information
  • Add to cart
Compare