Features
• Dedicated data logger for sensors and devices with RS232 output
(including environmental monitoring instruments, scales and NMEA devices)
• Data from two serial devices combined into one data record
• Data sampled and time-stamped then stored in daily files
• Simple to configure for wide range of devices – via Setup file written to SD card
• Option to record status of two switches
• SD card for high capacity data storage in easily removable and transferable format
• Compact, economical and robust design
• Low power consumption
• File format .CSV enables stored data to be read & analysed with standard PC software

Product Description

S10 Data Logger Overview

The SpaceLogger S10 is a versatile serial data logger for sampling RS232 data from up to two devices.

Data is stored on a removable memory card (included), enabling remote data logging without the need for direct connection to a PC. After logging, the memory card can be simply inserted in a card reader, to view and analyse the data on a PC; no special software is required.

Each data record combines the data from the two devices or from the two samples from one device. This record is date and time-stamped when it is stored. A new file is generated for each day’s data. The default file format is .CSV; other file extensions may be specified.

To configure the SpaceLogger S10 for a wide range of devices with RS232 output, set up includes defining the start and end characters for up to two data samples, baud rate, sample rate, file name format, handling of un-printable characters, addition of a separator and/or a newline to each data record. There is also the option to disable time-stamping and data sampling (to log all data).

The SpaceLogger S10 may be set up to output RS232 data as it is input or as logged. This enables connection to a PC, display or other device. A response to a handshake may be output and/or the contents of a file on the SD card may be set to output on start-up; this enables a command to be sent to the sensor, for example.

The status of two switches to ground may also be added to each data record. The unit records data to an SD card. These cards are available with up to 2GB capacity for long term data logging (included). The SpaceLogger S10 is ideal for field data acquisition due to its low power consumption and high capacity data storage.

Customised versions and quantity discounts are available – please contact our sales team for a quote.


SpaceLogger S10 Configuration Settings

The SpaceLogger S10 is configured for different devices using file SETUP.TXT written to the SD card.

File SETUP.TXT may contain the following commands:

WAIT Puts SpaceLogger in ‘wait’ mode for clock synchronisation
TIME Time at which clock will be synchronised
DATE Date at which clock will be synchronised
STX Defines the start character(s) of the first data sample to be logged
ETX Defines the end character(s) of the first data sample to be logged
SENTENCE2 Controls whether a second data sample is monitored for and logged
STX2 Defines the start character(s) of the second data sample to be logged
ETX2 Defines the end character(s) of the second data sample to be logged
LOGSTX Controls whether the characters defined by STX are logged or not
LOGETX Controls whether the characters defined by ETX are logged or not
LOGSTX2 Controls whether the characters defined by STX2 are logged or not
LOGETX2 Controls whether the characters defined by ETX2 are logged or not
SEPARATOR Enables addition of a comma separator before the second data sample
NEWLINE Adds <CR><LF> to end of each data sample
TIMEOUT Sets a time limit within which the next ETX, STX2 or ETX2 must be detected after the first STX before the logger jumps on to await next data sample (in seconds)
RX2 Enables monitoring of the second RS232 input (Input 2)
BAUD Sets baud rate for RS232 data input and output
PARITY Sets number of data bits and parity for RS232 input and output
RATE Sets the sample rate/logging interval
SINGLEFILE Sets logging to one continuous log file rather than daily files
FILE Modifies file name and extension format
TIMESTAMP Switches date & time stamping on or off
OUTPUT Controls RS232 output of data to RS232 Output 1
HANDSHAKE Enables transmission of response string defined by RESPONSE on receipt of one of STX, ETX, STX2 or ETX2 or at a time interval defined by RATE
RESPONSE Defines ASCII character string to be output on receipt of handshake string, as specified by HANDSHAKE
LOG_ALL Disables sampling of data via STX and ETX commands so that all data is logged
RAW Controls modification of unprintable characters (those of value <10) to <SP> characters
STARTUP Controls output of file STARTUP.TXT content to RS232 Output 1
SWITCH Enables logging of status of switches on Digital I/O terminals
RX_INV Controls logic inversion of the received data
RESET Returns logger to default settings

Typical Applications

• Environmental sensors e.g. wind speed and direction, temperature, humidity, pressure, noise, pollution
• GPS and other NMEA devices
• Weighing balances and scales
• Measuring equipment and analysers including flow meters, mix & dose units and counters
• Barcode scanners & RFID readers

Example of SpaceLogger S10 application

SpaceLogger S10 applicationExample of SpaceLogger S10 application
Sample and time-stamp data from devices with RS232 output

Additional information

Variant

Complete unit, *PCB ONLY* with screwless terminal, *PCB ONLY* wtih solder connections

Physical Enclosure dimensions Width: 67 mm
Depth: 67 mm
Height: 28 mm (excluding optional rubber feet)
Weight 75g
Enclosure material GP ABS (UL94-HB) plastic and acrylic
Connections Type Screwless terminals capable of accepting wire 0.32 to 0.64 mm diameter, (AWG 28 to 22 conductors)
RS232
Input 1
Transmission standard RS232 and TTL/CMOS* logic compatible.
*VIL Input threshold low: 0.6V min 1.2V Typ.
VIH Input threshold high: 1.5V Typ, 2.4V max
8 bits and no parity (default), even or odd parity or 7 bits and even or odd parity.
Logic inversion on received data is selectable.
Transmission speed 9600 Baud (default) or selectable to 115200, 57600, 38400, 19200, 4800, 2400 or 1200 Baud
Data Sample Records only the data between specified start (STX/STX2) and end (ETX/ETX2) identifiers (unless configured to LOG_ALL=Y)
RS232
Input 2
Transmission standard RS232 compatible, 8 bits and no parity only
Transmission speed 4800 Baud only
Data Sample Records only the data between specified start (STX2) and end (ETX2) identifiers (unless configured to LOG_ALL=Y)
Switch Inputs Max input voltage Must not exceed 3V
Current out 7μA max
RS232
Output 1
Transmission standard RS232 compatible, 8 bits and no parity (default), even or odd parity or 7 bits and even or odd parity
Transmission speed 9600 Baud (default) or selectable to 115200, 57600, 38400, 19200, 4800, 2400 or 1200 Baud
Data transmission Output of data defined by command OUTPUT. Output of handshake response unless already allocated to output data. Output of file STARTUP.TXT.
RS232
Output 2
Transmission standard RS232 compatible, 8 bits and no parity only
Transmission speed 4800 Baud only
Data transmission Only used for handshake response if RS232 Output 1 is already allocated to output data.
Data Storage Data storage card Removable SD
Data capacity 2 GByte (max)
File system FAT16 or FAT32 with 8.3 file names
Sector size 512 Bytes
Data logging interval Default is to log every data sample output by the device/sensor or select logging interval from 1 to 60 seconds. Data sampling may be disabled so all data is recorded.
Audible / Visual
Indicators
LED indicators Green: Ready to record data
Red: Power on | Writing data to SD card | Waiting for second data sample in timeout mode
Audio bleeper Two tone signal on correct card insertion
Single tone when data purge button depressed
Four bleeps per minute when time and date not set
Real Time Clock Accuracy ±40 ppm at 25°C
Backup battery CR2032
Power Power requirement 7 to 30 V DC
Current at 12 VDC 10 mA typical
Supply input protection Polarity reversal protected and internal resettable fuse – 140 mA
Connection options (both included) 1.3 mm centre pin DC connector, or Screwless terminals (0.32 to 0.64 mm diameter, AWG 28 to 22 conductors)
Environmental Temperature range Operating: -25°C to +70°C [or dependent on card conditions]
Storage: -40°C to +70°C
Enclosure protection IP203
EMC EMC Directive 89/336/EEC – CE marked
(Emissions: EN61326:1997 inc A1/A2/A3:2003, EN60945:1997
Immunity: EN61326:1997)
FCC/CFR 47: Part 15:2004

The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change.

Data Sheet
Download PDF SpaceLogger S10 – Data Sheet

 

User Manual
Download PDF SpaceLogger S10 – User Manual

 

Product Brochure
Download PDF SpaceLogger Sales Flyer (Weighing) GB

 

has been added to the cart. View Cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Price
  • Additional information
  • Add to cart
Compare