with FREE UK Standard Delivery
£ Call for more informationThe SpaceLogger D50 Wireless has been designed specifically for the medical decontamination device market.
The data logger connects via an RS232 serial port to the autoclave, washer disinfector or ultrasonic cleaner and wireless uploads all cycle data output by the device to a local area network. Data may be encrypted by the logger and each line of the file has a checksum applied to ensure security of the data.
![]() 24 HOUR SHIPPING
Processing Mon-Frion all in-stock models |
![]() FREE UK DELIVERY
Free standard deliveryNext day delivery available |
![]() RETURN POLICY
Not 100% satisfied?Return within 21 days |
The SpaceLogger D50 Wireless communicates wirelessly with a PC with the SpaceLogger Cycle Manager Software installed, via a Wi-Fi wireless local area network (WLAN). One copy of the SpaceLogger Cycle Manager Software may connect to multiple loggers within the same WLAN at any time.
• Enables the process of cycle data collection by a decontamination device operator to be as automated and user-friendly as possible.
• Enables real-time logging to PC of cycle records from multiple decontamination devices, via a wireless network. No need for the operator to transfer records via a memory card or paper print out. The operator obtains instant notification of a passed or failed cycle on any device at the PC.
• Provides management of cycle records for each device and creation of automated PDF reports.
• Allows user sign-off of each cycle (via PC) to release the batch.
• Enables electronic recording of each device's Daily & Weekly Tests and creation of an automated PDF report each week.
A local Wi-Fi network is required for remote access to the data stored on the logger. If this is temporarily unavailable, data may be downloaded directly from the SD card to a PC if it is removed from the SpaceLogger.
Configuration of the SpaceLogger for the WLAN is via a simple set-up file written to the SD card. This is generating using the SpaceLogger Real Time Cycle Manager Software.
Customised versions and quantity discounts are available - please contact our sales team to discuss.
• Secure digital logging of all decontamination cycle data - from sterilisers, washer disinfectors and ultrasonic cleaners
• Wireless transfer of data to PC for real-time viewing of cycles
• Efficient and accurate management of cycle records and reporting with the SpaceLogger software
• Time-saving automated Daily/Weekly Test Record completion with PDF output
• RS232 connection to decontamination device
• Compact, economical and robust design
• Micro SD or SDHC card for data storage
• Upgrade machines to comply with latest decontamination guidelines and best practice
• Recording and storage of operating data from laboratory and medical devices for record-keeping.
e.g. autoclaves and sterilisers, glassware washer-disinfectors.
• Cycle data from the SpaceLogger D50 Wireless data logger is uploaded in real-time automatically from any loggers within the local Wi-Fi network to the SpaceLogger Real Time Cycle Manager Software.
• The SpaceLogger Real Time Cycle Manager Software maintains a secure duplicated electronic record of every cycle on a PC.
• Individual cycle records may be viewed and cycle failure or security status issues are highlighted.
• Cycles may be 'released' or 'released with comment' via electronic sign-off.
• Appropriate cycles may be assigned as the Daily and Weekly test cycles and other operator tests & checks signed off to complete the Daily/Weekly Test Record for each decontamination device.
• A choice of PDF reports may be quickly created as required.
• The Real Time Cycle Manager Software is also used to generate a configuration file to activate the SpaceLogger D50 Wireless to operate with a specific decontamination device and to connect it wirelessly to the local WLAN.
Physical | Enclosure dimensions | Width: 67 mm Depth: 92 mm Height: 28 mm (excluding optional rubber feet) |
Weight | 100g | |
Enclosure material | GP ABS (UL94-HB) plastic and acrylic | |
Transmission standard | RS232 compatible, 8 bits and no parity | |
Transmission speed | Default 9600 Baud, 19200, 38400, 57600 also available | |
Connection | OEM specific: 9-way D-type, RJ12 | |
Wireless Connectivity | Configuration | WiFi Protected Setup (WPS) |
Wireless module | Wi-Fi Certified 2.4GHz IEEE 802.11b/g 802.11i Security WPA2-PSK, WPA, WEP | |
Aerial | Internal | |
Data Storage | Data storage card | Removable Micro SDHC card |
Data capacity | 8 GByte (standard) or as per memory card capacity | |
File system | FAT32 with 8.3 file names Sector size 512 Bytes |
|
Data logging interval | 1 Hz | |
Audible / Visual Indicators |
LED indicators |
Micro SD card: Green (card present) Data Status: Green (recording data) WiFi Status: Green (connected to wireless network) Status: Red (configuration in progress) |
Audio bleeper | Status alert | |
Real Time Clock | Accuracy | ±40 ppm at 25°C |
Power | Power requirement | 5 V DC ±10% |
Current at 5 VDC | 200 mA typical | |
Connection | Micro USB connector | |
Environmental | Temperature range | Operating: -25°C to +70°C [or dependent on card conditions] Storage: -40°C to +70°C |
Enclosure protection | IP203 | |
EMC | CE marked - EMC Directive 2004/108/EC |
The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change.
Data Sheet | |
---|---|
![]() |
SpaceLogger D50 Wireless - Data Sheet |
User Manual | |
---|---|
![]() |
SpaceLogger D50 Wireless - User Manual |
Gwennap Head National Coastwatch Weather Station | |
Richard Paul Russell has provided a complete internet connected weather station utilising a SpaceLogger W50 for the National Coastwatch Institution at Gwennap Head in Cornwall. The Gill Metpak weather sensor data is captured by the W50 data logger enclosed in the WeatherFile Connection Unit (WCU) and then transferred via the W50's Wi-Fi module to the Local area network and the internet. The live and historic wind speed, wind direction, pressure, temperature and humidity data can then be viewed on any internet connected device via the WeatherFile website. Richard Paul Russell have over 70 weather systems all using SpaceLogger W50s viewable on the WeatherFile website. |
|
Ryde Pier, Isle of Wight, Wind Data | |
This takes the Solent WeatherFile network to five sites and is an essential resource for sailors, water sport enthusiasts, sailing event organisers and others wishing to have live and accurate wind speed and direction measurements. One of the main challenges faced when fitting this unit was to overcome the lack of a local power supply and Wi-Fi internet access. Our newly developed WeatherFile Mobile Unit (WMU) containing a W50 and associated 4G router allows data to be gathered directly from the Gill MaxiMet GMX200 sensor and sent to our WeatherFile website. This was locally powered through a deep cycle leisure battery (70Ahr) connected to a solar panel. The result is cable free live data through WeatherFile completely independent of mains power and local internet. |
Industrial Emissions Monitoring Data | |
|
|
Milk Pasteurizer Machine Data Back-up | |
Why this logger is so critical is that the normal method of recording the data requires a degree of manual interaction, and if this does not occur for some reason, the entire batch cannot be sold due to the lack of pasteurization data. |
Mapping Conditions & Life on the Sea Bed | |
The SpaceLogger S10 data loggers were part of the equipment on three 3000 metre depth rated 'pods' along with batteries, video processing equipment and control electronics. Marcus Shirley of Mr ROV, a member of the research team, confirmed back to us: "The loggers worked great and allowed us to reliably record accurate data which we were able to easily import into our scienfic modelling software. The time stamping feature allowed us to sync up all the data with the logged data from the ship's GPS and vehicle USBL position transponder, creating a very comprehensive data set. Many thanks for your help. The SpaceLogger S10 data loggers were great and 100% reliable, which is very important when you're on a ship far from land!" |
|
New Zealand Lamb Weighing System | |
|
|
Straits of Malacca & Singapore Shipping Data | |
|
|
Vehicle Activated Signs Data | |
|
|
Bombardier Transportation Rail Vehicle Data | |
|
|
Load Cells with 4-20mA Output | |
The SpaceLogger A10 may take up to two 4-20mA analogue output. Readings are sampled at 75Hz, averaged over 1 second and time and date stamped when stored. The SpaceLogger A10 can be daisy chained for multiple load cell monitoring. Data is captured in a daily .csv file for easy analysis within a spreadsheet. If required conditional logging can be utilised. |
|
Outside Webcasting Services | |
|
|
Manufacturing Quality Control For Water Softener Filters | |
|
Warehouse Loading Bay Wind Data | |
|
|
Industrial Emissions Monitoring Data | |
|
|
Gwennap Head National Coastwatch Weather Station | |
Richard Paul Russell has provided a complete internet connected weather station utilising a SpaceLogger W50 for the National Coastwatch Institution at Gwennap Head in Cornwall. The Gill Metpak weather sensor data is captured by the W50 data logger enclosed in the Weatherfile Connection Unit (WCU) and then transferred via the W50's Wi-Fi module to the Local area network and the internet. The live and historic wind speed, wind direction, pressure, temperature and humidity data can then be viewed on any internet connected device via the WeatherFile website. Richard Paul Russell have over 50 weather systems all using SpaceLogger W50s viewable on the WeatherFile website. |
|
Ryde Pier, Isle of Wight, Wind Data | |
This takes the Solent WeatherFile network to five sites and is an essential resource for sailors, water sport enthusiasts, sailing event organisers and others wishing to have live and accurate wind speed and direction measurements. One of the main challenges faced when fitting this unit was to overcome the lack of a local power supply and Wi-Fi internet access. Our newly developed WeatherFile Mobile Unit (WMU) containing a W50 and associated 4G router allows data to be gathered directly from the Gill MaxiMet GMX200 sensor and sent to our WeatherFile website. This was locally powered through a deep cycle leisure battery (70Ahr) connected to a solar panel. The result is cable free live data through WeatherFile completely independent of mains power and local internet. |
|
Scottish Airport Cloud Ceilometer Data | |
This development has allowed Richard Paul Russell to enter the small airfield market with equipment system supply for comprehensive live wind, weather and visibility data. |
Eschmann Technologies Dental Autoclave Real-Time Cycle Data Management | |
The hardware customisation was in the areas of enclosure, brand labelling and over-moulded cable assembly. The software development was extensive to interpret the cycle data, allow manual input of additional tests and checks, facilitate user data analysis and present the combined data in the desired summary and detailed formats including Eschmann branded pdfs. This was a relatively complex project that has provided Eschmann customers with an on-going very successful product, that is still standing the test of time some 10 years after first use. |
|
Prestige Medical's Dental Decontamination Autoclave Cycle Logging | |
The most recent customisation was for a re-designed PCB-only logger to be built-in to a new autoclave design, with particular requirements for the SD card interface with the autoclave control panel fascia. This involved a new PCB layout to accommodate several changes including a new push-push SD card connector. |
|
MDS Medical's Dental & Veterinary Autoclave Data Management System | |
|
|
Large Scale Plasma Sterilizer Data | |
The data logger is shipped to Renosem's manufacturing facility as PCB-only for internal fitting in their plasma sterilizers. The SD card, LED indicators and purge button are all accessible through a faceplate in the outer casing of the sterilizer. The data is saved in daily text files, replicating the format that would be seen on a traditional paper printer-out. |
Eschmann Technologies Dental Autoclave Real-Time Cycle Data Management | |
The hardware customisation was in the areas of enclosure, brand labelling and over-moulded cable assembly. The software development was extensive to interpret the cycle data, allow manual input of additional tests and checks, facilitate user data analysis and present the combined data in the desired summary and detailed formats including Eschmann branded pdfs. This was a relatively complex project that has provided Eschmann customers with an on-going very successful product, that is still standing the test of time some 10 years after first use. |
|
Warehouse Loading Bay Wind Data | |
The W100 with a wired LAN connection is particularly valuable for safety critical applications such as this, and also where Wi-Fi is unreliable. |
|
On-board Vehicle Bin Weighing Systems | |
Further developments in this area have included Wi-Fi connectivity to allow direct data transfer as soon as soon as refuse or grit/salt spreader vehicles return to base. |
|
Mettler Toledo Laboratory Weigh Scales | |
The SpaceLogger T10 model is ideal for balances with a print command and RS232 output and will keep a text record identical to the paper print-out. Hence the requirement for a dedicated printer on the lab bench is removed. |
|
Prestige Medical's Dental Decontamination Autoclave Cycle Logging | |
The most recent customisation was for a re-designed PCB-only logger to be built-in to a new autoclave design, with particular requirements for the SD card interface with the autoclave control panel fascia. This involved a new PCB layout to accommodate several changes including a new push-push SD card connector. |
|
Scottish Airport Cloud Ceilometer Data | |
This development has allowed Richard Paul Russell to enter the small airfield market with equipment system supply for comprehensive live wind, weather and visibility data. |
|
MDS Medical's Dental & Veterinary Autoclave Data Management System | |
|
|
Large Scale Plasma Sterilizer Data | |
The data logger is shipped to Renosem's manufacturing facility as PCB-only for internal fitting in their plasma sterilizers. The SD card, LED indicators and purge button are all accessible through a faceplate in the outer casing of the sterilizer. The data is saved in daily text files, replicating the format that would be seen on a traditional paper printer-out. |