Temp, Humidity & Pressure | Air Pressure / Temperature | |
Relative / Absolute humidity | ||
Naturally aspirated UV stable radiation shield | ||
Protection against wind-blown precipitation/dust | ||
Solar Radiation | Complies with ISO 9060 & WMO Guidelines | |
Output in watts per metre2 | ||
180° hemispherical field of view | ||
Records sunshine hours | ||
Integrated Hukseflux LP02 pyranometer | ||
Glass dome | ||
Wind | Wind speed & direction | |
Apparent and true wind (with GPS) | ||
WMO wind averages and gust | ||
Compass | ||
GPS (Option) | Height above sea level m | |
Sunrise/sunset | ||
Position of the sun | ||
Twilight | ||
Solar Noon | ||
MSL pressure | ||
Parameters | Solar radiation W/m2 | |
Sunshine hours hrs | ||
Temperature °C / °F / °K | ||
Relative humidity % Rh | ||
Barometric pressure hPa, mbar, mm Hg, In Hg | ||
Wet bulb temperature °C / °F / °K | ||
Absolute humidity g/m3 | ||
Air density kg/m3 | ||
Wind speed m/s, hm/hr, mph, kts, ft/min | ||
Wind direction ° | ||
Wind chill °C / °F / °K | ||
True/apparent wind | ||
Angle of Tilt | ||
Outputs RS232, 422, 485 (ASCII), SDI-12, NMEA, MODBUS, Analogue (option) | ||
Wind Speed | Range | 0.01 m/s to 60 m/s |
Accuracy | ± 3% to 40 m/s, ± 5% to 60 m/s |
|
Resolution m/s | 0.01 | |
Starting Threshold | 0.01 m/s | |
Sampling Rate | 1 Hz | |
Units | m/s, km/hr, mph, kts, ft/min | |
Wind Direction | Range | 0-359° |
Accuracy | ± 3% to 40 m/s, ± 5% to 60 m/s |
|
Resolution | 1° | |
Starting Threshold | 0.05 m/s | |
Sampling Rate | 1 Hz | |
Units | Degrees | |
Temperature | Range | -40°C to +70 °C |
Resolution | 0.1 | |
Accuracy | ± 0.3°C @ 20°C | |
Sampling Rate | 1 Hz | |
Units | °C, °F, °K | |
Humidity | Range | 0-100% |
Resolution | 1% | |
Accuracy | ± 2% @ 20°C (10%-90% RH) | |
Sampling Rate | 1 Hz | |
Units | % Rh, g/m3 | |
Dew Point | Range | -40°C to +70°C |
Resolution | 0.1 | |
Accuracy | ± 0.3°C @ 20°C | |
Units | °C, °F, °K | |
Sampling Rate | 1 Hz | |
Pressure | Range | 300 to 1100 hpa |
Resolution | 0.1 hPa | |
Accuracy | ± 0.5 hPa @ 25°C | |
Sampling Rate | 1 Hz | |
Units | hPa, mbar, mmHg, inHg | |
Global Solar Radiation | Wavelength Sensitivity | 300 to 3000 nm |
Output Range | 0 to 1600 W/m2 | |
Resolution | 1 W/m2 | |
DIN Standard | ISO 9060 Second Class | |
Sampling Rate | 1 Hz | |
Units | W/m2 | |
Outputs | Output rate | 1/s, 1/min, 1/hr |
Digital Comms Modes | Serial RS232, RS422, RS485, SDI-12, NMEA, MODBUS, ASCII | |
Analogue Outputs | Available via seperate optional device | |
Power | Power Supply | 5 to 30 Vdc |
Power (Nominal) 12 Vdc | 25 mA continuous high mode 0.7 mA eco-power mode (1 hour polled) | |
Environmental Conditions | IP Rating | 66 |
Operational Temperature Range | -40°C to +70°C | |
EMC Standard | BS EN 61326 : 2013 FCC CFR47 parts 15.109 |
|
CE Marking | Yes | |
RoHS compilant | Yes | |
Weight | 0.8 Kg | |
Origin | UK |
Precipitation Care & Maintenance
NOTE: the temperature, humidity and barometer sensors are located internally and are not maintainable or replaceable by a user. Consideration should be given to checking the pressure readings against a standard every 12 months and maintaining the temperature and humidity sensor every 12-24 months. If required you can return the MaxiMet to Richard Paul Russell Ltd to check the barometer calibration, please contact us at sales@r-p-r.co.uk for more details.